Natural gas purification wastewater is mainly divided into normal production wastewater and maintenance wastewater.
The concentration of pollutants in normal production wastewater is low and can be treated by general biochemical treatment.
The maintenance sewage contains a large number of complex biodegradable substances, biodegradability is poor, for many years mainly rely on fresh water dilution treatment and combustion furnace treatment, but these two methods are low efficiency and high cost, so it is necessary to develop new wastewater treatment methods.
Although we have studied the upflow anaerobic sludge bed reactor (UASB) for the treatment of high concentration sewage of the natural gas purification plant, the start-up test results of 133 days show that the effluent COD removal rate is only about 40% when the influent COD is 6000mg/L, and the treatment effect is not good.
Therefore, it is of practical significance to explore and seek an effective pretreatment method.activated carbon wholesale
In this paper, Fenton oxidation and activated carbon adsorption were combined to pretreat the wastewater from natural gas purification maintenance, in order to improve the subsequent operation efficiency of UASB.
This experiment by orthogonal test to determine the Fenton reagent oxidation first preliminary operating conditions, on this basis, carries on the single factor analysis method, the main factors influencing the Fenton reagent treatment effect for each study, investigation of its influence on wastewater COD removal rate, the results show that Fenton oxidation method the optimum operating conditions for natural gas purification overhaul wastewater treatment: HO2 dosing quantity 0.3 mol/L, n (HO)/n (Fe) = systematically, initial pH = 3, reaction temperature 70 ℃, reaction time, 40 min.activated carbon for gold recovery
Sponsor
Bu konudaki kullanıcılar
Guest
Forumu Atla  
Bu foruma yeni konular postalayamazsınız.
Bu forumda ki konulara yeni posta gönderemezsiniz.
Bu forumdaki postalarınızı silemezsiniz.
Bu forumdaki postalarınızı düzenleyemezsiniz.
Bu forumda anketler yaratamazsınız.
Bu forumdaki anketlere oy veremezsiniz.

-->
Ateşleme trafoları,ozon trafolarıMaxwell Heroes(Beta)